ASM Access Floor Panel, Concrete-Filled, 1500, HPL
ASM Access Floor Panel, Concrete-Filled, 1500, HPL are epoxy-coated solid panels filled with lightweight cement and rated for static design loads of 1250lbs and is factory-laminated with a high-pressure laminate finish.
To receive an email quote, select a quantity and click Add to Quote.
For more assistance please contact our sales department via phone at +1 (888) 247-0986 x2 or by email at sales@team-prosoure.com.
ASM Access Floor Panel, Concrete-Filled, 1500, HPL are epoxy coated unitized shells consisting of a flat steel top sheet welded to a formed steel bottom pan filled with a highly controlled mixture of lightweight cement. Manufactured to exacting tolerances, these non-combustible, rigid, solid panels deliver the ultimate in strength, durability, and acoustic performance. ASM concrete-filled panels are suitable for almost any application and are factory laminated with HPL. The most widely used product in the data center industry, the FSD Series provides superior strength and durability. In today's ever-changing data center market, the need for a strong & dependable floor system to handle static and rolling loads has become the standard.
FSD-Series Performance Guide
Panel | Concentrated Design Load (i.) | Safety Factor (ii.) MIN. 2x | Uniform Loads | Impact Loads | Rolling Loads 10 PASS | Rolling Loads 10K PASS | |||||
(lbf) | (kN) | (psf) | kg/m² | (lb) | (kg) | (lbf) | (kN) | (lbf) | (kN) | ||
FS100D | 1000 | 4.45 | PASS | 500 | 2441.2 | 150 | 68 | 800 | 3.56 | 600 | 2.67 |
FS200D | 1250 | 5.56 | PASS | 600 | 2929.4 | 150 | 68 | 1000 | 4.45 | 800 | 3.56 |
FS300D | 1500 | 6.67 | PASS | 700 | 3417.7 | 150 | 68 | 1250 | 5.56 | 1000 | 4.45 |
FS400D | 2000 | 8.90 | PASS | 800 | 3905.9 | 200 | 91 | 1500 | 6.67 | 1250 | 5.56 |
FS500D | 2500 | 11.12 | PASS | 900 | 4394.2 | 200 | 91 | 2000 | 8.90 | 2000 | 8.90 |
FS600D | 3000 | 13.34 | PASS | 1000 | 4881 | 300 | 136 | 2700 | 12.01 | 2400 | 10.68 |
i. Concentrated Design Load is based on permanent set < and is verified by loading panels in accordance with the CISCA concentrated load method, but with panels installed on actual understructure instead of steel blocks. (Testing on blocks does not represent the performance of an actual installation.) Ultimate, Rolling, and Impact Load tests are performed using CISCA test procedures.
ii. Safety Factor is Ultimate Load divided by Design Load.